Trealamh Cumhachta Lasmuigh den Eangach Humsienk 24V - Ceallra LiFePO4 5.12kWh le Inverter Pure Sine Wave 4200W
Cumhacht Níos Mó, Fan Lasmuigh den Ghreille Níos Faide! Cumhachtach 5.12kWh Trealamh inbhéartóra ceallraí 24V atá tógtha le haghaidh cábáin, feithiclí áineasa, córais ghréine lasmuigh den ghreille, agus cumhacht chúltaca. Péireálann sé a Ceallraí LiFePO4 24V 200Ah móide le Inbhéirteoir tonn sine íon 4200W agus suas go dtí Ionchur PV 6200W, ag tabhairt níos mó acmhainne, aschur níos láidre, agus muirearú gréine solúbtha duit le haghaidh fearais laethúla oiriúnacha.
- Trealamh Cumhachta 5.12kWh — Ceallraí LiFePO4 24V 200Ah le hinbhéirtóir 4200W.
- Tonn Sín Íon 4200W — Cumhacht chobhsaí le borradh suas le 8400W.
- BMS 250A — Tacaíonn sé le hualaí ardchumhachta suas le 6400W.
- Ionchur Gréine 6200W — Tógtha le haghaidh córais ghréine níos mó lasmuigh den ghreille.
- Muirearú suas le 120A — Muirearú tapa ó fhuinneamh gréine, fóntais nó gineadóir.
What Can It Power?
Estimate how long the 24V 200Ah Plus battery can run your device with the 4200W pure sine wave inverter.
Estimated runtime only. Results are based on manual backup-time data where available; actual use may vary by load, startup power, battery condition and environment.
What’s Included & User Manuals
Check what comes with the 24V 200Ah Plus battery and 24V 4200W inverter, and download the user manuals before installation.
24V 200Ah Plus Battery Package
Please check the actual package contents after delivery.
- 24V 200Ah Plus LiFePO4 Battery × 1
- Additional battery accessories See actual package
24V 4200W Inverter Package
Based on the inverter user manual unpacking list.
- The Unit × 1
- User Manual × 1
Package contents are listed according to the available user manuals. Cables and additional installation accessories are not included unless otherwise stated.
Specifications
24V 200Ah Plus Battery
| Battery Model | 24V 200Ah Plus LiFePO4 Battery |
| Rated Voltage | 25.6V |
| Capacity | 200Ah |
| Energy | 5,120Wh |
| Standard / Maximum Continuous Charging | 40A / 250A |
| Max Continuous Discharge Current | 250A |
| Standard Charging Voltage | 29.2V ±0.2V |
| Cycle Life | 6000 cycles @80% DOD |
| Self-Discharge Rate | ≤3% per month |
| Series & Parallel Connection | Max. 2 series / 4 parallel |
| Dimensions | 25.00 × 9.61 × 8.58 in / 63.5 × 24.4 × 21.8 cm |
| Weight | 101.74 lb / 46.1 kg |
| Protection Rating | IP65 |
| Case Material | ABS+PC / UL94-V0 |
| Terminal Bolt Size | M8 |
| Battery Pack Certifications | IEC62133 / RoHS / CE / FCC / UN38.3 / Class 9 |
| Cell Certifications | UL1642 / UL2580 / UN38.3 |
| Storage Temperature | 32°F to 140°F / 0°C to 60°C |
24V 4200W Inverter Output
| Inverter Model | 4.2kW / 24V |
| Rated Output Power | 4200W / 4.2kW |
| Output Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230V AC ±5% |
| Output Frequency | 50Hz |
| Surge Capacity | 2× rated power for 5 seconds |
| Peak Efficiency | 93% |
| No-Load Power Consumption | 35W |
| Nominal DC Input Voltage | 24V DC |
| Cold Start Voltage | 23.0V DC |
| Low DC Cut-Off Voltage | 20.5V at load below 50% / 20.0V at load of 50% or above |
| High DC Cut-Off Voltage | 33V DC |
Solar & Charging
| Charging Algorithm | 3-Stage Charging |
| Maximum AC Charging Current | 100A |
| Bulk Charging Voltage | 29.2V for flooded battery / 28.2V for AGM or gel battery |
| Floating Charging Voltage | 27V DC |
| Solar Charger Type | MPPT |
| Maximum PV Array Power | 6200W |
| Nominal PV Voltage | 240V DC |
| PV Array MPPT Voltage Range | 60–500V DC |
| Maximum PV Array Open-Circuit Voltage | 500V DC |
| Maximum AC + Solar Charging Current | 120A |
AC Input & Power Sources
| Nominal AC Input Voltage | 230V AC |
| Input Voltage Waveform | Sinusoidal, utility or generator |
| Acceptable AC Input Range | 90–280V AC in Appliance Mode / 170–280V AC in UPS Mode |
| Maximum AC Input Voltage | 300V AC |
| Nominal Input Frequency | 50Hz / 60Hz, auto detection |
| Transfer Time | 10ms typical in UPS mode / 20ms typical in Appliance mode |
| Output Source Priorities | Utility First / Solar First / SBU Priority / MKS Priority |
| Charging Source Priorities | Solar First / Solar and Utility / Solar Only |
General & Protection
| Safety Certification | CE |
| Inverter Dimensions | 356 × 442 × 116 mm / 35.6 × 44.2 × 11.6 cm |
| Inverter Net Weight | 8.0 kg / 17.6 lb |
| Operating Temperature Range | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |
| Humidity | 5% to 95% relative humidity, non-condensing |
| Display | LCD display with function buttons |
| Output Short-Circuit Protection | Circuit breaker |
| Overload Protection | 3 seconds at ≥150% load / 5 seconds at 101%–150% load |
| Automatic Restart After Overload | Configurable |
| Automatic Restart After Over-Temperature | Configurable |
Specifications are based on the product user manuals. Runtime and output performance may vary depending on appliance power, startup load, wiring, battery condition and installation environment.