Inverter Pure Sine Wave Inverter Humsienk PULSAR 12V 1000W
TĂłgtha le haghaidh campĂĄlaithe, bĂĄid agus socruithe beaga lasmuigh den ghreille, seachadann an t-inverter tonn sine Ăon 12V 1000W seo cumhacht chobhsaĂ do chuisneoirĂ, soilsiĂș, rĂomhairĂ glĂșine agus leictreonaic laethĂșil. TacaĂonn a rialtĂłir MPPT ionsuite le... suas go dtĂ 600W de phainĂ©il ghrĂ©ine, agus coinnĂonn muirearĂș fĂłntais agus grĂ©ine do cheallraĂ rĂ©idh.
Aschur Tonn SĂn Ăon 1000W: Seachadann sĂ© cumhacht AC 230V cobhsaĂ do chuisneoirĂ, soilsiĂș, rĂomhairĂ glĂșine agus leictreonaic Ăogair i gcampĂĄlaithe, i mbĂĄid agus i gcĂłrais bheaga lasmuigh den ghreille.
Cumhacht Eagar PV suas le 600W: TacaĂonn sĂ© le suas le 600W de phainĂ©il ghrĂ©ine ceangailte le haghaidh bailiĂș fuinnimh Ă©ifeachtach i rith an lae.
MuirearĂș GrĂ©ine 40A MPPT: SolĂĄthraĂonn an rialtĂłir MPPT ionsuite suas le 40A de mhuirearĂș grĂ©ine do chĂłrais cadhnraĂ 12V comhoiriĂșnacha.
80A Sruth Muirir IomlĂĄn: TacaĂonn sĂ© le muirearĂș grĂ©ine agus fĂłntais chomhcheangailte suas le 80A chun cabhrĂș leis an gceallraĂ a athluchtĂș nĂos tapĂșla.
Cumas Borrtha 2000W: Seachadann sé dhå oiread na cumhachta aschuir råtåilte ar feadh suas le soicind amhåin chun déileåil le hualaà tosaithe gearra fearas.
TosaĂocht Cumhachta SolĂșbtha: Roghnaigh tosaĂocht fĂłntais ar dtĂșs, grĂ©ine ar dtĂșs nĂł SBU chun freastal ar riachtanais chumhachta Ă©agsĂșla lasmuigh den ghreille agus cĂșltaca.
Dearadh DlĂșth Lasmuigh den Ghreille: SĂĄbhĂĄlann an dearadh balla-fheistithe Ă©adrom 3.3kg spĂĄs i gcampĂĄlaithe, i mbĂĄid, i gcĂĄbĂĄin agus i gcĂłrais chumhachta beaga.
Choose Your 12V Battery Setup
Pair your 12V 1000W inverter with the right 12V LiFePO4 battery for RVs, boats, camping, small appliances, and backup power.
| Power Scenario | Typical Devices | Power Demand | Recommended Battery Setup | Battery Capacity |
|---|---|---|---|---|
| Essential 12V Backup Basic backup use | Lights / Wi-Fi / Phone Charging / Small Fan / TV | Light Load For daily essentials and small devices | 1.28â2.05 kWh | |
| Extended Runtime Setup RV & camping power | Fridge / Freezer / TV / Laptop / Coffee Maker / Small Pump | Medium Load Longer backup time with more capacity | 2.56â4.02 kWh | |
| Maximum Runtime Large-capacity 12V backup | RV / Boat / Off-grid Cabin / Longer Backup Use / Multiple Appliances | Heavy Runtime Large 12V battery capacity for longer use | 4.10â8.19 kWh |
đĄ Tip: This is a 12V inverter. Use a 12V battery system only. Do not connect batteries in series, as series connection increases the voltage to 24V or higher. For longer runtime, choose a larger 12V battery or connect identical 12V batteries in parallel only if supported by the battery manual.
Estimate Your 12V Backup Time
Choose a common load or enter your own power usage to estimate how long each 12V battery setup can keep your inverter running.
Choose Your Power Load
Not sure? Start with one of the common 12V inverter load presets below.
Estimated runtime = battery capacity Ă 90% usable energy Ă· power load.
Essential 12V Backup
Compact 12V capacity for lights, Wi-Fi, phone charging, small fans, and TV.
Extended Runtime Setup
More capacity for RVs, boats, camping, small pumps, laptops, and longer daily use.
Maximum Runtime
Large-capacity 12V backup for longer RV, marine, cabin, and off-grid use.
Estimated runtime is for reference only. Actual performance may vary depending on appliance power, inverter efficiency, battery settings, temperature, and installation conditions. This is a 12V inverter. Use a 12V battery system only. Do not connect batteries in series, as series connection increases the voltage to 24V or higher.
Specification
General
| Model | HSINV12V1KW220-SRA-EU |
| Dimensions (L Ă W Ă H) | 9.45 Ă 3.58 Ă 11.26 in / 240 Ă 91 Ă 286 mm |
| Net Weight | Approx. 3.3 kg / 7.28 lb |
| Operating Temperature | 14°F to 122°F / -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |
| Humidity | 5% to 95% RH, non-condensing |
| Installation | Wall-mounted |
| Compliance | CE |
Inverter Output
| Rated Output Power | 1000W / 1000VA |
| Output Waveform | Pure Sine Wave |
| Output Voltage | 230V AC ±5% |
| Output Frequency | 50Hz |
| Surge Capacity | 2000W for up to 1 second |
| Peak Inverter Efficiency | 94% |
| No-Load Power Consumption | Less than 28W |
| Overload Protection | 3 seconds at â„150% load / 5 seconds at 101%â150% load |
| Output Short-Circuit Protection | Circuit breaker |
Solar Input
| Maximum PV Array Power | 600W |
| Solar Charger Type | MPPT |
| MPPT Voltage Range | 20â150V DC |
| Maximum PV Open-Circuit Voltage | 150V DC |
| Maximum Solar Charging Current | 40A |
Battery & Charging
| Nominal Battery Voltage | 12V DC |
| Maximum AC Charging Current | 40A |
| Maximum Solar + AC Charging Current | 80A |
| Charging Algorithm | 3-Stage Charging |
| Default Bulk Charging Voltage | 14.1V |
| Default Float Charging Voltage | 13.5V |
| Low DC Cut-Off Voltage | 10.75V at load below 50% / 10.5V at load of 50% or above |
| High DC Cut-Off Voltage | 16.0V |
AC Input & Power Sources
| Nominal AC Input Voltage | 230V AC |
| Acceptable AC Input Range | 90â280V AC in Appliance Mode / 170â280V AC in UPS Mode |
| Nominal Input Frequency | 50Hz / 60Hz, auto detection |
| Maximum AC Input Voltage | 300V AC |
| Transfer Time | 10ms |
| Supported Power Sources | Solar, Battery, Utility and Generator |
| Output Source Priorities | Utility First / Solar First / SBU Priority / MKS Priority |
| Charging Source Priorities | Solar First / Solar and Utility / Solar Only |
Display & Protection
| Display | LCD display with function buttons |
| AC Output Connection | Hardwired AC output and built-in output receptacles |
| Anti-Dust Kit | Optional removable anti-dust filter |
| Automatic Restart After Overload | Configurable |
| Automatic Restart After Over-Temperature | Configurable |
| Over-Temperature Protection | Supported |
| Short-Circuit Protection | Supported |
| High and Low Voltage Protection | Supported |
| Fault and Warning Display | LCD fault codes with audible alarm |
Product specifications are based on the latest available technical documentation. Installation must be completed by qualified personnel in accordance with local electrical and safety regulations.